材料
Online ISSN : 1880-7488
Print ISSN : 0514-5163
ISSN-L : 0514-5163
埋設鋼管の交流電流による腐食の評価法
柏木 愛一郎野中 英正西川 明伸木下 明
著者情報
ジャーナル フリー

2004 年 53 巻 11 号 p. 1180-1185

詳細
抄録
There is a possibility that alternating current will cause corrosion in a defect of the coating on buried steel pipeline. In this research, we developed an evaluating method with which we could evaluate alternating current corrosion of the steel in a short time compared with conventional evaluating method by mesuring corrosion weight loss. The results of this research showed that alternating current corrosion of buried steel under cathodic protection could be estimated by measuring the IR-drop-free potential, especially peak (maximum) potential of the steel using IR-drop-free probe. It was also found that corrosion protection of the steel could be achieved when peak potential of the steel was over 100mV less noble than free corrosion potential of the steel.
著者関連情報
© 日本材料学会
前の記事 次の記事
feedback
Top