Japanese Journal of Oral Diagnosis / Oral Medicine
Online ISSN : 2188-2843
Print ISSN : 0914-9694
ISSN-L : 0914-9694
Original
New Trial of Direct Verbal Input for Dental Examination Records
HIROYUKI KOMETANISEIZABURO ARITAIKIKO TSUJIHIROTAKA TATSUMIMAMORU KOMEDAAKIO OHNISHIKYOKO HIGUCHI
Author information
JOURNAL FREE ACCESS

2018 Volume 31 Issue 3 Pages 193-198

Details
Abstract
We have reported methods for directly inputting oral examination records and plaque control records (PCR) into a computer using speech recognition software. However, since the terms and input methods were determined for the straightforward input of each type of record, two software programs, one for oral examination records and one for PCR, were necessary. Therefore, in this study, an input method that is applicable to various examinations was evaluated.
Verbalizations of dentists examining the oral cavity were collected using a microphone, and data were converted to text using speech recognition software and directly input into a computer. AmiVoice Ex Clinic was used as the speech recognition software. The tooth numbers were defined as ichiban to hachiban. Oral examination records, PCR, and records of the periodontal pocket depth (1-point method) were produced in 20 cases. Data input was performed 5 times in each case, and the input time was measured. The input recognition error rate was also evaluated.
Oral examination records, PCR, and records of the periodontal pocket depth could be verbally input. This method is applicable to the input of various dental examination records.
Content from these authors
© 2018 The Japanese Society of Oral Diagnosis / Oral Medicine
Next article
feedback