Journal of the Japan Society for Precision Engineering, Contributed Papers
Online ISSN : 1881-8722
Print ISSN : 1348-8724
ISSN-L : 1348-8716
Paper
Filtered LQ Control for an Anti-Vibration Unit with Piezo-Element
Shinji WAKUIMakoto HOSHIKan AKATSU
Author information
JOURNAL FREE ACCESS

2004 Volume 70 Issue 6 Pages 823-827

Details
Abstract
Anti-vibration units have been developed to realize micro-vibration circumstance. Recently, the anti-vibration units using the piezo-elements have been widely developed. For these units having the velocity sensors to detect the vibration of structure, the full state feedback can be applied to improve the transmissibility from the floor vibration. However, there is a weak point so that the large displacement of piezo-element is excited for an impulsive floor vibration. Considering the time constant of piezo-driver, it is considered that its displacement is substantially relieved. In fact, a pointed piezo-displacement becomes zero owing to the time constant of driver. On the contrary, the transient response easily becomes a vibrational wave form, namely unstable.
Then, in this paper, the Filtered LQ control is proposed to ensure both the stability of control loop and the zero response for impulsive input. First, the state equation including the dynamics of piezo-driver is shown. Next, the role of feedback parameters is clarified in comparison with the ordinary state feedback. Finally, this paper shows that high quality transmissibility is realized coping with both the stability and the avoidance of sudden response.
Content from these authors
© 2004 The Japan Society for Precision Engineering
Previous article Next article
feedback
Top