原著
光学3次元人体形状計測法に基づく体表面積の推定式の開発
設楽 佳世高井 洋平太田 めぐみ若原 卓金久 博昭福永 哲夫川上 泰雄
著者情報
ジャーナル フリー

2009 年 58 巻 4 号 p. 463-474

詳細
抄録

This study was conducted to examine the reliability of three-dimensional photonic image scanning (3DPS) for measuring body surface area (BSA), and formulate equations for predicting BSA based on 3DPS. The surface area (SA) of a cylinder with known SA and BSA of 7 males were repeatedly measured by 3DPS. BSA was determined by 3DPS for 122 subjects (25–76 yrs). BSA prediction equations for both genders were developed for the validation group (16 males and 45 females) using body height and mass as independent variables, and were cross-validated for the cross-validation group (16 males and 45 females). The standard error of measurement was 2.2cm2 (0.16%). The coefficients of variation (CV) for repeated measurements of SA were less than 0.2%. The BSA of subjects did not differ significantly on any given day nor between days, with a CV of less than 1%. The coefficient of determination and standard error of estimation of the prediction equations were 0.98 and 183cm2 (1.1%), respectively, for males and 0.98 and 204cm2 (1.3%), respectively, for females. There was no significant difference between the predicted and measured values. In the cross-validation group, there was no significant difference between the predicted and measured values without systematic errors. These findings indicate that 3DPS is reliable for measuring BSA, and the formulated equations are valid and applicable to individuals within a wide age-range.

著者関連情報
© 2009 一般社団法人日本体力医学会