スマートプロセス学会誌
Online ISSN : 2187-1337
Print ISSN : 2186-702X
ISSN-L : 2186-702X
高温密閉型エレクトロケミカルマイグレーションの発生メカニズムと対策
髙木 晶子浅見 愛吉田 久彦佐久間 陽也
著者情報
ジャーナル フリー

2022 年 11 巻 5 号 p. 215-220

詳細
抄録
High-temperature enclosed electrochemical migration (ECM) is one of the new defects in the board assembly that occurs at the sealed bottom electrode when the device gets heated with running for a long period of time. This defect can also occur in the dry conditions unlike ordinary ECM. We have developed a novel method that can easily reproduce this phenomenon so that the migration behavior can be observed. The formation of high-temp enclosed ECM is caused by movement of the metal ions, when the flux residue underneath the electrode is soft and has high fluidity. Therefore, it can be prevented by optimizing the elastic modulus of the flux residue at the component operating temp. This approach is effective even if the flux residue contains a large amount of activators such as organic acids.
著者関連情報
© 2022 一般社団法人 スマートプロセス学会
前の記事 次の記事
feedback
Top