鋼構造論文集
Online ISSN : 1884-0329
Print ISSN : 1880-9928
ISSN-L : 1880-9928
極軟鋼せん断パネルダンパーの静的および動的低サイクル疲労性能
張 超鋒袁 輝輝青木 徹彦
著者情報
ジャーナル フリー

2012 年 19 巻 73 号 p. 73_21-73_32

詳細
抄録
The low cycle fatigue tests of low yield strength steel shear panel damper (LYSPD) are carried out under a constant amplitude sin wave to verify the ductility performance. Four shear strain amplitudes (20%, 30%, 40% and 50%) are applied to the LYSPD in the static and dynamic loading based on three kinds of periods (static, 2 sec and 1 sec). The hysteretic characteristic, fatigue life and failure mode are obtained and compared between the static and dynamic tests. Although the dynamic test results showed that the LYSPD has large deformation capacity as well as high energy dissipation ability and good low cycle fatigue performance, these characteristics are deteriorated with the high temperature caused by high strain speed and intemal friction. In order to evaluate the dynamic performance of LYSPD rationally, the strain speed and high temperature should be taken into consideration.