鋼構造論文集
Online ISSN : 1884-0329
Print ISSN : 1880-9928
ISSN-L : 1880-9928
一般論文
ダンパー取付部材の破断によって生じる地震時最大応答逆転現象の小型模型振動台実験による検証
辻 聖晃小川 勇大藤田 皓平
著者情報
ジャーナル フリー

2019 年 26 巻 104 号 p. 104_17-104_24

詳細
抄録

Shaking table tests of small scale building model with oil damper are performed in order to verify an earthquake response magnification phenomenon caused by fracture of damper attachment member during earthquake motion. Fracture of damper attachment member is simulated by means of detachable steel block which links a oil damper with a floor plate. The steel block is detached from the floor plate at any timing by switching on an electro magnet. It is shown that the characteristics of earthquake response magnification ratios which are observed in the shaking table tests correspond well to those which are simulated by numerical analysis.

著者関連情報
© 2019 社団法人 日本鋼構造協会
前の記事 次の記事
feedback
Top