This study is planed to clear the behaviour of friction joints with high strength bolts on web bolted flange welded (WBFW) connections. Test parameters are the width to thickness ratio(D/t ratio) of the column and existence of weld connection between shear plate and beam web. And to make clear detailed behaviour, FEA is carried out. The results are briefly shown: when the D/t ratio is large, it has little effect on the behaviour of the WBFW connection. But in the case of web welded connection, flexural strength of the connection increases as the D/t ratio decreases. This phenomena is caused by increasing of the moment which is transmitted in beam web. Proposed evaluation of flexural strength in this paper is good correspondence with the test results.