鋼構造論文集
Online ISSN : 1884-0329
Print ISSN : 1880-9928
ISSN-L : 1880-9928
大きなセットバックを有する超高層ビルの設計
伊藤 優
著者情報
ジャーナル フリー

1995 年 2 巻 6 号 p. 45-56

詳細
抄録
ACT TOWER, ACT CITY HAMAMATSU, has a large setback at a height of 120m, where the hotel lies over the office part . There are three main themes in the structural design. The first is the solution to use a Super truss for the framing of the setback part . The second is that the site is located in a very high seismic area. Evaluated earthquake waves are made considering this, and the design is checked. And the third is the wind resistant design. It is confirmed that the building behavior is almost elastic for the case of a storm in 500 years return period. Semi-active mass dampers are set up to improve comfortability for the case of strong winds within a year.
著者関連情報
© 社団法人日本鋼構造協会
前の記事
feedback
Top