鋼構造論文集
Online ISSN : 1884-0329
Print ISSN : 1880-9928
ISSN-L : 1880-9928
通しダイアフラム形式で角形鋼管柱に接合されるH形鋼梁の塑性変形能力に関する実大実験
その2.工場溶接形式(梁:H-500×200×10×16)試験体に対する実験
田渕 基嗣森田 耕次田中 剛上場 輝康
著者情報
ジャーナル フリー

1997 年 4 巻 16 号 p. 43-58

詳細
抄録

This paper presents the results of tests conducted for beam-column subassemblages having a beam section of H-500×200×l0×lb (Grade : SS400) and jointed by a method of shop-welding type. A total of 27 specimens were tested, with the type of connection details, type of run-off tabs, method of welding, thickness of through diaphragm, and temperature as test variables. Major findings include that (1) the specimens with improved scallops are superior in plastic deformation capacity to those with conventional scallops; (2) specimens with welding of one path per layer and steel run-off tabs show lower plastic deformation capacity, in which cracks initiated from the toe of weld caused brittle fracture along the heat affected zone of weld.

著者関連情報
© 社団法人日本鋼構造協会
前の記事 次の記事
feedback
Top