JAPAN TAPPI JOURNAL
Online ISSN : 1881-1000
Print ISSN : 0022-815X
ISSN-L : 0022-815X
Operating Experience of Heat Recovery System for Calcined Lime
Tadashi Izawa
Author information
JOURNAL FREE ACCESS

1980 Volume 34 Issue 1 Pages 104-108

Details
Abstract
The BHK's Fuller Air Quenching Cooler is attached to the discharge end of the lime kiln and it is successfully operated.
The results were summerized as follow :
1) The calcined lime coaled from 1, 120 °C to 220 °C by air, the heat recuperation efficiency was 83 %.
2) Fuel consumption is decreased more than 15% (1/2 by cooler, 1/2 by another effect)
Add : Radiation loss from kiln shell is decreased about 1/3 4/4 by the use of some adiabatic concreate for refractory brick.
Content from these authors
© Japan Technical Association of the Pulp and Paper lndustry
Previous article Next article
feedback
Top