Journal of the Textile Machinery Society of Japan
Online ISSN : 1881-1159
Print ISSN : 0040-5043
Automatic Control of Short Term Sliver Irregularities by the Detection of Drafting Force
Shoichi IshikawaJiro Shimuzu
著者情報
ジャーナル フリー

1962 年 8 巻 3 号 p. 41-50

詳細
抄録
A new instrument that measures drafting force continuously and eliminates short term variations in sliver weight has been developed by the authors (Figs. 1, 2).
The electronic instrument consists of magnetic power amplifiers (Fig. 3) with a loop transfer function H (S) as given by eq. (6).
The instrument has been found to successfully reduce short term sliver weight irregularities. The effect of loop gain and time constant on sliver irregularity has also been investigated. Also by changing the corner frequency ωa of the instrument, the effect of ωa on the wave length of sliver irregularities has been obtained (see Fig. 18).
著者関連情報
© The Textile Machinery Society of Japan