Journal of UOEH
Online ISSN : 2187-2864
Print ISSN : 0387-821X
ISSN-L : 0387-821X
A Passive Tobacco Smoke Exposure System for Laboratory Animals
Isamu TANAKASumiyo ISHIMATSUToshiaki HIGASHITakahiko KATOHTakashi AKIYAMA
Author information
JOURNAL FREE ACCESS

1990 Volume 12 Issue 1 Pages 37-42

Details
Abstract
A simple passive tobacco smoke exposure system was developed for laboratory animals. The system consisted of a tobacco smoke generator and an exposure chamber. Performance testing was conducted using Fischer 344 rats. The rats were exposed to passive tobacco smoke generated by 20 cigarettes per day for 3 months. The concentration of the cigarette smoke aerosol (particle phase) in the chamber can be kept almost constant during exposure. The daily average mass concentration was 10.0±4.3 mg/m3 and the carbon monoxide was 79±22 ppm during exposure.
Content from these authors
© 1990 The University of Occupational and Environmental Health, Japan
Previous article Next article
feedback
Top