抄録
This study made clear the flow field in a wall attachment amplifier using the hydrogen bubble method.
The model of fluidic element for visualization was Flip-Flop type logical unit. The working fluid was water. The experiments was done in the range of Reynolds number 200-700, and the control flow was changed from 0 to 20% in each case.