Journal of the Visualization Society of Japan
Online ISSN : 1884-037X
Print ISSN : 0916-4731
ISSN-L : 0916-4731
Manufacture of the capacitance tomography sensor for real plants and electrical characteristics of catalvst
Kenta MASAKIMasahiro TAKEIRyoji OGISOKoji NAKAO
Author information
JOURNAL FREE ACCESS

2006 Volume 26 Issue Supplement2 Pages 181-182

Details
Abstract
We have conducted a basic experiment on visualization of a pipe which is used for transport catalyst in industrial use. First two copper-electrodes are attached to inner side and outer side of the container. We have charged 5volt to the interelectrode and have changed frequency from 5kHz to 100kHz to obtain stable capacitance. The experiment has two conditions that container is filled with catalyst or air. The stable conditions have been confirmed at the time more than 50kHz. We have made a CT sensor with 12 electrodes attached to the pipe which has diameter of 270mm based on the experiment result.
Content from these authors
© The Visualization Society of Japan
Previous article Next article
feedback
Top