真空技術
Online ISSN : 1883-7182
ISSN-L : 1883-7182
電離真空計の指度に及ぼす油の逆拡散の影響について
岡本 宏章
著者情報
ジャーナル フリー

1956 年 7 巻 2 号 p. 71-78

詳細
抄録
Indication of an ionization gauge is frequently fluctuated abnormal due to the deposit of oil vapour.
In this report I treated the effect of constructive material and of the temperature of envelope.The clean-up of the surface of constructive material depends merely on the temperature of material and is prominent at about 330°C, and if the temperature of envelope is kept about at 100°C, the abnormal out-gassing phenomenon will decrease.
著者関連情報
© 日本真空協会
次の記事
feedback
Top