Journal of the Vacuum Society of Japan
Online ISSN : 1882-4749
Print ISSN : 1882-2398
ISSN-L : 1882-2398
Review
Reducing Particle Contamination During Pump-down in Load Lock Chamber
Hiroyuki KOBAYASHI
Author information
JOURNAL FREE ACCESS

2010 Volume 53 Issue 10 Pages 568-572

Details
Abstract
  Reducing both pump-down time and particle contamination in load lock chambers is important for the vacuum apparatus to improve productivity in semiconductor device manufacturing. In this study, particles that became detached from the chamber wall and flew up in the chamber during pump-down were observed with an in-situ particle monitor. Particles attached to a wafer surface were also counted using a wafer inspection system. The dependence of the number of flying particles on pump-down time constant τ agreed with the dependence of the number of particles attached to the wafer surface on τ. Thus, it was deduced that the in-situ particle monitor was useful for determining a suitable pump-down speed. Furthermore, when the pump-down speed was increased, fast particles were generated, which damaged the fine photoresist patterns.
Content from these authors
© 2010 The Vacuum Society of Japan
Previous article Next article
feedback