風環境評価のための三杯型風速計と超音波型風速計による統計量の差の検討
赤星 明紀猿川 明佐々木 亮治宮下 康一中村 修植松 康
著者情報
ジャーナル フリー

2018 年 43 巻 3 号 p. 91-99

詳細
抄録

The criterion for wind environment assessment by Wind Engineering Institute Co., Ltd. is based on the relation between the mean wind speeds measured by 3 cup anemometers and the surrounding condition. Recently, ultrasonic anemometers with lower cost and higher performance has become popular and taken place of 3 cup anemometers; 3-cup anemometers respond to the wind speed change slowly for lower wind speeds while they tend to over-rotate for higher wind speeds due to the effect of inertia force. Considering this circumstances, the present paper investigates the difference between 3 cup anemometer and ultrasonic anemometer for the measured values. Based on the results, we propose a correction method for converting the measured values by 3 cup anemometers to those by ultrasonic anemometers.