Pipe-end Flow Meter
T. KuzuokaT. HosodaS. Terauchi
Author information
JOURNAL FREE ACCESS

1953 Volume 17 Issue 9 Pages 336-339

Details
Abstract

Flow-rate u0[cm/sec] of the liquid from the end of a horizontal pipe (Fig. 1) can be calculated by measuring the distance x[cm] at the given level S[cm].
(4)
The experimental results obtained from water stream in the glass, brass and copper pipes showed that the coefficient C is constant in any case, and nearly equals 1.00 (C=1.00±0.02≅1), when u0≥120cm/sec.

Content from these authors
© by THE SOCIETY OF CHEMICAL ENGINEERS, JAPAN