Journal of the Mass Spectrometry Society of Japan
Online ISSN : 1880-4225
Print ISSN : 1340-8097
ISSN-L : 1340-8097
報文
Flowing Afterglow: Construction of an Apparatus, Measurement of Rate Constants, and Consideration of the Diffusive Behavior of Charges
Shingo MatsuokaHirone NakamuraToshihiro FujiiTakaaki Tamura
著者情報
ジャーナル フリー

1984 年 32 巻 2 号 p. 253-262

詳細
抄録
A flowing afterglow apparatus was constructed and the operation of the afterglow system including data analysis was tested by measuring the rate constants for the reactions N+ + NO, N2+ + NO, He+ + N2, and SF6 + e; the results were 5.8 × 10-10, 3.9 × 10-10, 1.20 × 10-9, and 2.1 × 10-7 cm3s-1 respectively. In the measurements an extraction voltage for ion sampling was not applied to the nose cone in order not to introduce an electric field into the reaction region. A "non-ambipolar" model developed by us was used for the data analysis of the ion/molecule reactions. For the data analysis of the electron attachment, a typical curve fit mehtod to the product ion signal was used. However, no theoretical curves fit the experimental points. This disagreement is attributed to a change of the ion-sampling efficiency through the nose-cone aperture arising from a change of the electron-dominated plasma to a negative-ion-dominated plasma with an increasing flow rate of SF6. Nevertheless, the attachment rate could be determined by fitting the theoretical and experimental curves in the limited region of the SF6 flow rate where the negative-ion-dominated plasma is established at the sampling aperture. All the rate constants obtained here agree reasonably well with literature values. Next, errors in the positive ion/molecule reaction rate constants, which would occur if the diffusion coefficients of the ions and neutrals each have a +10% error were calculated for the flow model to be -0.4 and +1.2 % respectively, demonstrating that these parameters are not important in the analysis of data. This insensitivity explains why the nose-cone voltage applied in a typical flowing afterglow operation has not caused a significant error in the published rate constants although it disturbs the ion diffusive behavior.
著者関連情報
© 1984 by The Mass Spectrometry Society of Japan
前の記事 次の記事
feedback
Top