Journal of the Mass Spectrometry Society of Japan
Online ISSN : 1880-4225
Print ISSN : 1340-8097
ISSN-L : 1340-8097
技術報告
On-Line SPE LC/APCI-MS/MSを用いた高感度自動化分析
—ヒト血漿中プラバスタチンおよびその主代謝物の測定法—
川端 清浦崎 葉子
著者情報
ジャーナル フリー

2005 年 53 巻 2 号 p. 79-87

詳細
抄録
A method by liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry (LC/APCI-MS/MS) for the quantitative determination of pravastatin and its main metabolite (R-416) in human plasma with a fully automated on-line solid-phase extraction (SPE) system, PROSPEKT-2TM was established. The method employed the direct on-line injection of human plasma into the PROSPEKT-2TM system for extraction of the analytes followed by column switching introduction of analytes to the LC/APCI-MS/MS system. The use of on-line SPE system resulted in reducing the sample preparation time and decreasing endogenous interfering substances in the extracts. The lower limit of quantification (LLOQ) for the assay was 0.1 ng/mL for pravastatin and R-416 on a 100 μL plasma sample. The calibration curves were linear for concentrations ranging from 0.1 to 100 ng/mL for both analytes. The intra- and inter-assay precisions were less than 4%. The method provides an automated sample analysis in a total cycle time of 6 min, allowing the analysis of many plasma samples to be conducted with increased throughput and improved robustness.