Journal of the Mass Spectrometry Society of Japan
Online ISSN : 1880-4225
Print ISSN : 1340-8097
ISSN-L : 1340-8097
Utilization of Neutral Particle Beam in Ion Microanalyzer
Hisashi KobayashiKen'ichi SuzukiYoshiaki YanagisawaKen'ichi Yukawa
Author information
JOURNAL FREE ACCESS

1977 Volume 25 Issue 4 Pages 315-323

Details
Abstract

A separating apparatus for the primary ion beam and the neutral particle beam which is attached to Ion Microanalyzer(IMA), is developed.And the characteristics of the neutral beam, such as the sputtering yields, the secondary ion yields and the beam density, are examined.The sputtering yields and the secondary ion yields of the oxygen neutral particle beam are the same as those of the O2+ion beam.The neutral particle beam density is depending-on the discharging condition of a hollow cathode ion gun. In addition, the analysis method using the neutral particle beam is discussed.This method not affected by the charge built up phenomena of a sample and is suitable for obtaining the stable mass spectra of the insulators such as glasses or organic materials.

Content from these authors
© The Mass Spectrometry Society of Japan
Previous article Next article
feedback