Voxel-based Morphometry of Alzheimer’s Disease Using a Localizer Image: A Comparative Study with Magnetization Prepared Rapid Acquisition with Gradient Echo
Shohei InuiDaita KanedaKeita Sakurai Yuto UchidaOsamu AbeYoshio Hashizume
Author information
JOURNAL OPEN ACCESS

2025 Volume 24 Issue 1 Pages 103-111

Details
Abstract

Purpose: Magnetization prepared rapid acquisition with gradient echo (MPRAGE) sequence is a gold-standard technique for voxel-based morphometry (VBM) because of high spatial resolution and excellent tissue contrast, especially between gray matter (GM) and white matter (WM). Despite its benefits, MPRAGE exhibits distinct challenge for VBM in some patients with neurological disease because of long scan time and motion artifacts. Speedily acquired localizer images may alleviate this problem. This study aimed to evaluate the feasibility of VBM using 3D Fast Low Angle Shot image captured for localizer (L3DFLASH).

Methods: Consecutive 13 patients with pathologically confirmed Alzheimer’s disease (AD) (82 ± 9 years) and 21 healthy controls (HC) (79 ± 4 years) were included in this study. Whole-brain L3DFLASH and MPRAGE were captured and preprocessed using the Computational Anatomy Toolbox 12 (CAT12). Agreement with MPRAGE was evaluated for L3DFLASH using regional normalized volume for segmented brain areas. In addition to brain volume difference on VBM and Bland-Altman analysis, atrophic pattern of AD on VBM was evaluated using L3DFLASH and MPRAGE.

Results: Acquisition time was 18 s for L3DFLASH and 288 s for MPRAGE. There was a slight systematic difference in all regional normalized volumes from L3DFLASH and MPRAGE. For the whole cohort, GM volume measured from MPRAGE was greater than that from L3DFLASH in most of the region on VBM. When AD and HC were compared, AD-related atrophic pattern was demonstrated in both L3DFLASH and MPRAGE on VBM, although the difference was noted in significant clusters between them.

Conclusion: Although systematic difference was noted in regional brain volume measured from L3DFLASH and MPRAGE, AD-related atrophic pattern was preserved in L3DFLASH on VBM. VBM, using speedily acquired localizer image, may provide limited but useful information for evaluating brain atrophy.