Magnetic Resonance in Medical Sciences
Online ISSN : 1880-2206
Print ISSN : 1347-3182
ISSN-L : 1347-3182
INNOVATIVE CLINICAL IMAGE
4D Flow MRI Reflects Physiological Hemodynamics for the Diagnosis and Management of Portosystemic Shunts
Atsushi Higaki Akira YamamotoToshimasa OkadaTomio UenoYasuyuki TomiyamaKosuke ItoTsutomu Tamada
Author information
JOURNAL OPEN ACCESS
Supplementary material

2025 Volume 24 Issue 2 Pages 149-154

Details
Abstract

A woman in her sixties with portosystemic shunt and hepatic encephalopathy underwent open mesenteric vein ligation, resulting in improved portal flow and blood ammonia. In this case, 4D flow MRI was a valuable diagnostic and follow-up tool, visualizing and quantifying physiological portal hemodynamics with features distinct from those of contrast-enhanced CT and digital subtraction angiography. Our case study highlights the value of 4D flow MRI for managing portosystemic shunts.

Content from these authors
© 2025 by Japanese Society for Magnetic Resonance in Medicine

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Next article
feedback