Assessment of Improved Motion-Sensitized Driven Equilibrium (iMSDE) for Multi-contrast Vessel Wall Screening
Makoto OBARA Marc VAN CAUTERENMasatoshi HONDAYutaka IMAIKagayaki KURODA
著者情報
キーワード: black blood, MRI, MSDE, vessel wall imaging
ジャーナル フリー 早期公開

論文ID: 2013-0036

この記事には本公開記事があります。
詳細
抄録
Purpose: We assessed the improved motion-sensitized driven equilibrium (iMSDE) technique for multiple contrast 3-dimensional vessel wall imaging at 3T.
Methods: Carotid images were obtained using iMSDE combined with turbo field echo (iMSDE-TFE) and conventional double inversion-recovery turbo spin-echo (DIR-TSE) in 5 healthy adult subjects. The tissue signal-to-noise efficiency (SNReff), SNR divided by the square root of scan time, lumen-tissue contrast-to-noise efficiency (CNReff), CNR divided by the square root of scan time, and tissue signal intensity ratio (SIR) were measured in both techniques and compared.
Results: The iMSDE-TFE had higher SNReff and CNReff (P < 0.01) and strong correlation in SIR (R = 0.92) compared to DIR-TSE.
Conclusion: The iMSDE-TFE sequence is an efficient technique for vessel wall screening.
著者関連情報
© 2014 by Japanese Society for Magnetic Resonance in Medicine