Magnetic Resonance in Medical Sciences
Online ISSN : 1880-2206
Print ISSN : 1347-3182
ISSN-L : 1347-3182

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

MR Imaging-based Evaluation of Mesenteric Ischemia Caused by Strangulated Small Bowel Obstruction and Mesenteric Venous Occlusion: An Experimental Study Using Rabbits
Akitoshi InoueNorihisa NittaShinichi OtaKai TakakiYugo ImaiSayaka MisakiTakayasu IwaiAkinaga SonodaKen-Ichi MukaishoKiyoshi Murata
著者情報
ジャーナル オープンアクセス 早期公開

論文ID: mp.2019-0010

この記事には本公開記事があります。
詳細
抄録

Purpose: This study assessed the MRI findings of strangulated small bowel obstruction (SBO) and mesenteric venous occlusion (MVO) in a rabbit model using 3T MRI.

Materials and Methods: Twenty rabbits were included in this study. The strangulated SBO and MVO models were generated via surgical procedures in nine rabbits, and sham surgery was performed in two rabbits. The success of generating the models was confirmed via angiographic, macroscopic, and microscopic findings after the surgical procedure. MRI was performed before and 30 min after inducing mesenteric ischemia. T1-weighted images (T1WIs), T2-weighted images (T2WIs), and fat-suppressed T2WIs (FS-T2WIs) were obtained using the BLADE technique, and fat-suppressed T1WIs (FS-T1WIs) were obtained. The signal intensities of the affected bowel before and after the surgical procedures were visually categorized as high, iso, and low intense compared with the findings for the normal bowel wall on all sequences. Bowel wall thickness was measured, and the signal intensity ratio (SI ratio) was calculated using the signal intensities of the bowel wall and psoas muscle.

Results: Angiographic, macroscopic, and microscopic findings confirmed that all surgical procedures were successful. The ischemic bowel wall was thicker than the normal bowel. The bowel wall was thicker in the MVO model (3.17 ± 0.55 mm) than in the strangulated SBO model (2.26 ± 0.46 mm). The signal intensity and SI ratio of the bowel wall were significantly higher after the procedure than before the procedure on all sequences in both models. The mesentery adjacent to the ischemic bowel loop exhibited a high signal intensity in all animals on FS-T2WIs.

Conclusion: Non-contrast MRI can be used to evaluate mesenteric ischemia caused by strangulated SBO and MVO. FS-T2WIs represented the best modality for depicting the high signal intensity in the bowel wall and mesentery caused by ischemia.

著者関連情報
© 2019 by Japanese Society for Magnetic Resonance in Medicine

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
feedback
Top