頸動脈IMT計測における検者間の検討
永江 学杉原 浩高橋 洋一本間 宏之清水 裕冶
著者情報
ジャーナル フリー

2004 年 17 巻 3 号 p. 148-150

詳細
抄録

IMT measurement is useful of the evaluation of early arteriosclerotic change. Using images preserved on IMT equipment, we made a comparison of measurements carried out by three independent examiners. We also carried out measurements using the IMT measurement software installed in the equipment. Two of the three examiners showed good correlation of their measurement values, and a high correlation with the results of automatic analysis was also recognized. Automatic measurement provided a very high correlation with usual measurement when there was no hard plaque. Areas where there was hard plaque or bending did not show a high correlation among the three examiners. These findings highlight the need to improve IMT assessments made by examiners.

著者関連情報
© 2004 日本脳神経超音波学会