Neurosonology:神経超音波医学
Print ISSN : 0917-074X
ISSN-L : 0917-074X
CCF症例における内頸動脈塞栓術後の血行動態
―TCDと脳血管撮影像との対比―
谷口 典男近藤 秀樹槇永 剛一安部 嘉男西窪 良彦乾 正
著者情報
ジャーナル フリー

1992 年 5 巻 1-2 号 p. 20-24

詳細
抄録

Using transcranial Doppler sonography (TCD) and angiography, we studied the hemodynamics of basal cerebral arteries of one patient with a carotid-cavernous sinus fistula (CCF) after internal carotid artery (ICA) embolization. The patient suffered traumatic left CCF and was treated with complete ICA embolization.
The results of TCD using commom carotid artery compression in measuring the blood flow velocity of vertebral, ophthalmic and middle cerebral arteries were mostly in accordance with those of the angiography.
However, comparing TCD with angiography, TCD is noninvasive and involves only a simple physiologi-cal examination, so by using TCD we can accurately diagnose and follow up cases such as this patient, easily and frequently.

著者関連情報
© 日本脳神経超音波学会
前の記事 次の記事
feedback