超音波を用いた頭蓋内圧演算システム―健康成人での検討
口脇 博治稲尾 意秀吉田 和雄杉田 虔一郎石井 直宏顧 遂平小倉 幸夫瀧下 利男佐久間 宣光
著者情報
ジャーナル フリー

1994 年 7 巻 3 号 p. 143-147

詳細
抄録
We investigated changes in thin layer thickness between the skull and the brain in association with changes in intracranial pressure (ICP) in human subjects using our ultrasound (UT) system.
A thin-disc-type prototype probe (5 MHz) was attached to the supra-auricular areas of seven adult volunteers. ICP was varied by changing posture between the sitting and supine positions, and Valsalva's maneuver, or neck compression in the supine position. Our UT system was triggered at 200 msec after the peak time of R wave on the ECG. The interference echoes from the thin layer were clearly visualized utilizing our revised algorithm of FFT-Cepstrum analysis with the maximum entropy method.
The thickness of the thin layer in the supine or sitting position decreased significantly during Valsalva's maneuver or neck compression in the supine position (Wilcoxon U test, p<0.05) . The thickness of the thin layer was quite similar to that of the dura mater. The reproducibility of the data was confirmed using theKolmogorov-Smirnov test.
Our ultrasound system for ICP measurement appears to be useful for estimating changes in ICP levels of human subjects.