NMC Case Report Journal
Online ISSN : 2188-4226
ISSN-L : 2188-4226
TECHNICAL NOTE
Alternative Proximal Protection Method during Carotid Artery Stenting Using Combined Transbrachial and Transradial Artery Approaches
Yuki HAMADAFumio MIYASHITAHideki MATSUOKAYuki NISHINAKAMAYusuke KAIYusuke YAMASHITAMei IKEDAGo TAKAGUCHIKeisuke MASUDAFumikatsu KUBOHiroshi TAKASHIMA
著者情報
ジャーナル オープンアクセス HTML

2023 年 10 巻 p. 273-278

詳細
抄録

Herein, we report a case of carotid artery stenting with proximal flow protection for severe stenosis of the left internal carotid artery using transbrachial and transradial artery approaches. Because an abdominal aortic aneurysm was present, we avoided the transfemoral approach. The procedure was successfully performed with a combination of an 8-Fr balloon guide catheter and microballoon catheter on separate axes. No complications such as pseudoaneurysm, thrombosis, or dissection were observed at the puncture site. The patient was discharged without complications and showed good outcomes at 3 months. This technique may offer a useful alternative for patients with severe stenosis who cannot be treated using a femoral artery approach.

Fullsize Image
著者関連情報
© 2023 The Japan Neurosurgical Society

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/