Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports
Saiko WatanabeKenichi AmagasakiKazuaki NaemuraHiroshi Nakaguchi
Author information
JOURNAL FREE ACCESS FULL-TEXT HTML Advance online publication

Article ID: cr.2014-0444

Details
Abstract
Two cases of exposed titanium mesh occurred after implantation for cranioplasty after repeated procedures for microvascular decompression (MVD). Case 1 was a 62-year-old female who underwent MVD for left hemifacial spasm followed by repair of cerebrospinal fluid leak after the surgery, and Case 2 was a 75-year-old female who underwent MVD twice for right trigeminal neuralgia. Both patients visited our hospital again with complaints of postauricular lesion. Titanium mesh was visible through the operative scar and was successfully removed with no complication in both cases. Both patients were underweight females, and combined with multistep surgery may have contributed to the pathology. The present cases suggest that use of titanium mesh should be avoided for cranioplasty of posterior fossa surgery, especially for repeated procedures.
Content from these authors
© 2015 The Japan Neurosurgical Society

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/