C-1-1 パーティクルフィルタを用いたFBI画像からの下肢血管領域の自動抽出(治療支援(1))
金 亨燮古賀 結子タン ジュークイ石川 聖二山本 晃義
著者情報
会議録・要旨集 フリー

詳細
抄録

Recently, the Arterio sclerosis obliterans (ASO) caused by chronic ischemia of limbs increases. As one of the diagnosis methods to detect the ASO, MR image which is obtained fresh blood imaging (FBI) is used for visual screening in medical fields. In this paper, we propose a method to detect blood vessel regions in legs from the FBI images. Especially, we developed for preventing the spread outside of the region and the segment accuracy in peripheral artery areas that is improved by using particle filter algorithms. We performed our proposed method on to real MR images which is obtained by FBI method and satisfactory detection results of artery regions are achieved.