カバードメタルステント留置により截石に成功した肝内結石の1例
久保井 頼子杉森 一哉近藤 新平久保 敦義石井 ゆにば亀田 英里三輪 治生石井 寛裕金子 卓粉川 敦史沼田 和司田中 克明前田 愼
著者情報
ジャーナル フリー

2015 年 86 巻 1 号 p. 212-213

詳細
抄録

A 77-year-old woman underwent pancreaticoduodenectomy and Child's reconstruction for advanced duodenal cancer in 2012. During the 18 months following surgery, the patient was admitted six times with repeated cholangitis. Computed tomography showed intrahepatic bile duct dilation due to stones in the left hepatic duct. Using a colonoscope and double-balloon scope, we were not able to detect the choledochojejunostomy. After performing percutaneous biliary drainage, we successfully used the rendezvous method for cannulation of the bile duct. We attempted to extend the stenosis of the choledochojejunostomy using a biliary balloon dilatation catheter ; however, we were not able to achieve sufficient dilatation through the severe stenosis. Therefore, we deployed a covered metallic stent (CMS) , to dilate the stenosis of the choledochojejunostomy. After achieving sufficient dilatation of the stenosis with the CMS extension, the CMS was removed. This procedure sufficiently dilated the severe stenosis of the choledochojejunostomy to allow for safe removal of the intrahepatic bile duct stones. Cholangitis did not recur for six months after the procedure.