Progress of Digestive Endoscopy(1972)
Online ISSN : 2189-0021
Print ISSN : 0389-9403
Technology and instrument
Results of Endoscopic Hemorrhoidal Ligation
Takesada GotoHideo YamadaTadashi HachisuKazuyuki MatsushitaShin-ichi SatoYoshihiko KinoshitaMotonobu NishimuraTeruo Kouzu
Author information
JOURNAL FREE ACCESS

1996 Volume 48 Pages 134-135

Details
Abstract
The usefulness of endoscopic hemorrhoidal ligation using Stiegmann's ligator was discussed. The advantages of this treatment are less pain and short hospitalization due to minimal invasive operation.
Thirty six cases were treated in this method and 33 cases (92%) showed excellent results. However, 3 cases needed following surgical operation because of post-ligated prolapsus in two patients and aggravation of external hemorrhoid in one patient. Thses 3 cases were patients with high grade hemorrhoids (Goligher's III, IV) .
We concluded that indication of endoscopic hemorrhoidal ligation should be limited to the low and middle grade hemorrhoids (Goligher's II, III) .
Fullsize Image
Content from these authors
© 1996 Japan Gastroenterological Endoscopy Society Kanto Chapter
Previous article Next article
feedback
Top