2016 年 11 巻 p. 2405089
ACT2 (Active Cooling Teststand 2), a high heat flux test facility using electron beam has been upgraded from ACT facility and started the operation. A new electron gun enables the steady state and transient heat load on actively cooled samples. ACT2 can achieve large loaded area with steady state reactor relevant heat flux (∼20 MW/m2) up to 200 × 200 mm2 and simulation of edge localized modes with short pulse length (∼100 µs). Beam profile was obtained about 9 mm with graphite probes. The heat flux is obtained by water calorimetry and measurement of the current through the samples.