2018 Volume 13 Pages 2406005
The authors have developed a nondestructive inspection method using backscattered neutrons to detect voids and water in concrete with a RIKEN Accelerator-driven Compact Neutron Source (RANS). In this study, neutrons are emitted to a slab sample that consists of a concrete layer and an asphalt layer, and position distribution of backscattered neutrons are measured at the timing from 0.1 to 0.5 ms. The two-dimensional position of water and voids in the concrete plate under asphalt (5 cm) of the slab sample are detected.