Plasma and Fusion Research
Online ISSN : 1880-6821
ISSN-L : 1880-6821
Regular Articles
Application of EMC3-EIRENE to Estimation of Influence of a Liquid Metal Limiter on an LHD-Type Fusion Plasma
Gakushi KAWAMURAJunichi MIYAZAWATakuya GOTOMamoru SHOJISuguru MASUZAKIYasuhiro SUZUKIYuhe FENG
Author information
JOURNAL FREE ACCESS

2018 Volume 13 Pages 3403034

Details
Abstract

Recently, a new limiter concept with liquid metal for a helical fusion reactor was proposed. This work present a modeling study to understand the influence of the limiter to the plasma and to find critical parameters for the liquid limiter concept. EMC3-EIRENE code is applied to a limiter configuration of a vertical column formed with plane surfaces at the inboard side of the Large Helical Device (LHD). The calculation results indicate that heat load on the helical divertor plates is significantly reduced when the limiter is inserted into the ergodic layer even without impurities. However, the influence of impurity radiation is too large in some cases. In order to achieve a large reduction of divertor flux and to avoid a large reduction of core electron temperature, parameter scans with limiter position and sputtering yield were performed. The results suggest that the limiter position is a critical parameter for acceptable degradation of the core and sufficient reduction of divertor flux.

Content from these authors
© 2018 by The Japan Society of Plasma Science and Nuclear Fusion Research
Previous article Next article
feedback
Top