Plasma and Fusion Research
Online ISSN : 1880-6821
ISSN-L : 1880-6821
Regular Articles
Measurement of Electron Temperature Profile and Fluctuation with ECE Radiometer System in Heliotron J
Maoyuan LUOKazunobu NAGASAKIGavin WEIRHiroyuki OKADATakashi MINAMIShinichiro KADOShinji KOBAYASHISatoshi YAMAMOTOShinsuke OHSHIMATohru MIZUUCHIShigeru KONOSHIMAYuji NAKAMURAAkihiro ISHIZAWA
Author information
JOURNAL FREE ACCESS

2020 Volume 15 Pages 2402038

Details
Abstract

A multi-channel electron cyclotron emission (ECE) radiometer system is being developed in Heliotron J to measure electron temperature (Te) profile and evaluate Te fluctuation. The conventional ECE part of this system includes 16 channels and can measure electron temperature profile from 58 GHz to 74 GHz which covers from the core to the edge region, and the correlation ECE part is composed of CECE-RF and CECE-IF sides. The signals from these two sides share a same source of electron cyclotron emission and thus are possible to estimate electron temperature fluctuation through correlation analysis. An ECE profile has been obtained and compared with data from Thomson scattering system in an electron cyclotron heated plasma. Electron temperature fluctuation levels were estimated in an ECH plasma using a cross-correlation function and a complex coherence function.

Content from these authors
© 2020 by The Japan Society of Plasma Science and Nuclear Fusion Research
Previous article Next article
feedback