Plasma and Fusion Research
Online ISSN : 1880-6821
ISSN-L : 1880-6821
Rapid Communications
First Application of an InfraRed Imaging Video Bolometer to Heliotron J Plasma
Akira MIYASHITAKiyofumi MUKAIShinsuke OHSHIMARyota MATOIKEByron J. PETERSONShinji KOBAYASHIHiroyuki OKADAShinichiro KADOTakashi MINAMITohru MIZUUCHIShigeru KONOSHIMAKazunobu NAGASAKI
Author information
JOURNAL FREE ACCESS

2021 Volume 16 Pages 1202079

Details
Abstract

The spatial radiation distribution has been measured with an infrared imaging video bolometer (IRVB) in a neutral beam injected (NBI) plasma from the Heliotron J device. The temperature distribution on the IRVB foil is consistent with radiation simulated by the three-dimensional transport code, EMC3-EIRENE. The foil temperature increase is proportional to the radiation intensity measured with an Absolute eXtreme UltraViolet (AXUV) diode diagnostic. These results suggest that the IRVB can be used for plasma radiation measurements in small and medium size devices.

Content from these authors
© 2021 by The Japan Society of Plasma Science and Nuclear Fusion Research
Previous article Next article
feedback
Top