Plasma and Fusion Research
Online ISSN : 1880-6821
ISSN-L : 1880-6821
Regular Articles
Extension of Operation Region for Steady State Operation on QUEST by Integrated Control with Hot Walls
Makoto HASEGAWAKazuaki HANADANaoaki YOSHIDAHiroshi IDEITakeshi IDOYoshihiko NAGASHIMARyuya IKEZOETakumi ONCHIKengoh KURODAShoji KAWASAKIAki HIGASHIJIMATakahiro NAGATAShun SHIMABUKUROKazuo NAKAMURA
著者情報
ジャーナル フリー

2021 年 16 巻 p. 2402034

詳細
抄録

The controllability of particle supply during long-term discharge in a high-temperature environment was investigated at the Q-shu University Experiment with steady state spherical tokamak (QUEST). QUEST has a high-temperature wall capable of active heating and cooling as a plasma-facing wall. With this hot wall, a temperature rise test was conducted with 673 K as the target temperature. It was confirmed that the hot wall could maintain the temperature above 600 K. Feedback control of particle fueling was conducted to control Hα emission, which is closely related to influx to the wall. Using this particle fueling control and setting the hot wall temperature to 473 K, it was possible to obtain a discharge of more than 6 h. In this discharge, the fueling rate of particles decreased with time, and finally became zero, losing the particle fueling controllability. However, as soon as the cooling water started to flow through the hot wall, particles could be supplied again, and controllability was restored. Thus, indicating that temperature control of the plasma first wall is important even in the high-temperature environment of 473 K to control particle retention of the wall.

著者関連情報
© 2021 by The Japan Society of Plasma Science and Nuclear Fusion Research
前の記事 次の記事
feedback
Top