Plasma and Fusion Research
Online ISSN : 1880-6821
ISSN-L : 1880-6821
Regular Articles
Heat Transfer Characteristics Evaluation of Multi-Elbow Cooling System for Fusion Divertor under One-Sided Heating
Shinji EBARAKenya MITOBEYukinori HAMAJIHidetoshi HASHIZUME
Author information
JOURNAL FREE ACCESS

2023 Volume 18 Pages 2405034

Details
Abstract

In this study, a cooling system for fusion reactor divertor that utilizes a swirling flow generated downstream of multi-elbow piping was proposed, and flow fields of the multi-elbow piping (triple elbow) were investigated using flow visualization experiment. Additionally, heat transfer experiment was conducted under one-sided heating condition to simulate a fusion reactor environment. The results revealed that the heat flux removed by the swirling flow in the elbow piping exceeded the critical heat flux in straight piping, and a heat removal performance of up to 25 MW/m2 was achieved.