Plasma and Fusion Research
Online ISSN : 1880-6821
ISSN-L : 1880-6821
Regular Articles
Relative Frequency Calibration for Fast Frequency Sweep Microwave Reflectometry
Akira EJIRIYoshiyuki SHIMADATakuma YAMADATakuya OOSAKOYuichi TAKASEHiroshi KASAHARA
Author information
JOURNAL FREE ACCESS

2007 Volume 2 Pages 040

Details
Abstract

A frequency-modulated reflectometer with a frequency band of 26.5 to 40 GHz has been constructed and installed in the TST-2 spherical tokamak to measure fast density profile evolution. In order to calibrate the instantaneous frequency for various frequency sweep rates, a waveform matching method has been proposed and applied to the reflectometer. This method compares the interference patterns (i.e., waveforms) of a fixed target reflection, which do not depend on the sweep rate, and obtains the instantaneous frequency by fitting the target waveform time to the time for a reference sweep waveform. This allows evaluation of output frequency stability. The overall frequency error, including reproducibility, is around 0.1 GHz. Sweep rates up to 20 μs were used to measure the density profile evolution during rf heating.

Content from these authors
© 2007 by The Japan Society of Plasma Science and Nuclear Fusion Research
Previous article Next article
feedback
Top