Plasma and Fusion Research
Online ISSN : 1880-6821
ISSN-L : 1880-6821
Regular Articles
Development of ECE Imaging System on LHD
Yuichiro KOGITakuya SAKODAAtsushi MASENaoki ITOSoichiro YAMAGUCHIYoshio NAGAYAMAKazuo KAWAHATA
Author information
JOURNAL FREE ACCESS

2007 Volume 2 Pages S1032

Details
Abstract
Electron cyclotron emission (ECE) imaging has been an important tool to investigate behaviors of temperature perturbations in the specific spatial area. So far, we have applied ECE detection system to a LHD plasma to measure electron temperature fluctuations in core region, however, it was difficult to distinguish perturbed temperature signals to a noise, which is naturally consisted in radiometry features and so on. Recently, we have optimized an ECE detector array especially in sensitivity to increase signal to noise ratio. An intermediate frequency(IF) system composed of commercial components have been replaced by an integrated system utilizing millimeter(microwave) integrated circuit technology(MIC) to fabricate a compact system maintaining the performance of the commercial system. As a result of application to the LHD plasma, we have successfully obtained ECE signal even in comparably low temperature operation sequence.
Content from these authors
© 2007 by The Japan Society of Plasma Science and Nuclear Fusion Research
Previous article Next article
feedback
Top