Plasma and Fusion Research
Online ISSN : 1880-6821
Regular Articles
Development of Real-Time Measurement System of Charge Exchange Recombination Spectroscopy and Its Application to Feedback Control of Ion Temperature Gradient in JT-60U
Shinji KOBAYASHIMaiko YOSHIDAHidenobu TAKENAGAShinya SAKATAYutaka KAMADAYoshiteru SAKAMOTOYoshihiko KOIDEthe JT-60 Team
Author information
JOURNALS FREE ACCESS

2007 Volume 2 Pages S1049

Details
Abstract

Real-time measurement system of the ion temperature profile has been developed for the feedback (FB) control of the ion temperature gradient (grad-Ti) with the filter charge exchange recombination spectroscopy (CXRS) system in JT-60U. The rapid analytical scheme without non-linear least square fitting enables us to calculate the ion temperature with four spatial points every 10 ms using a real-time processor system. The FB control experiment of grad-Ti has been demonstrated in ELMy H-mode plasmas by use of the neutral beam injectors having different deposition profiles as actuators. Grad-Ti was controlled to the reference value in the ramp-down phase, however, it did not recovered in the ramp-up phase because the internal transport barrier or transport was affected by the ramp-down of grad-Ti, From the transient response analysis of grad-Ti, the increase in the central Ti using the additional heating was required to recover the deteriorated grad-Ti.

Information related to the author
© 2007 by The Japan Society of Plasma Science and Nuclear Fusion Research
Previous article Next article
feedback
Top