Plasma and Fusion Research
Online ISSN : 1880-6821
ISSN-L : 1880-6821
Regular Articles
Advanced Probe Measurement System in TU-Heliac
Yutaka TANAKA, Hiromi TAKAHASHI, Hiroyasu UTOH, Michiaki OGAWA, Junji SHINDE, Hiroshi AOYAMA, Keisuke IWAZAKI, Hajime UMETSU, Atsushi OKAMOTO, Katsuhiro SHINTO, Sumio KITAJIMA, Masayuki YOKOYAMA, Shigeru INAGAKI, Yasuhiro SUZUKI, Kiyohiko NISHIMURA, Mamiko SASAO
Author information
JOURNAL FREE ACCESS

2007 Volume 2 Pages S1090

Details
Abstract
An advanced probe measurement system consisting of high-speed Langmuir probes with a preamplifier and a Copper shield was designed and installed in TU-Heliac. Potential and density fluctuations were measured in the hot-cathode biased plasma, and power spectra were calculated using the complex Fourier transform. There were low frequency fluctuations (f < 10 kHz), high frequency fluctuations (70 < f < 200 kHz) and sharp spectra applied for the plasma production (10 < f < 50 kHz). In the region above 200 kHz, the power decreased by a factor of 1/f2 for the potential fluctuation and 1/f2∼3 for the density fluctuation. The phase shift between potential and density fluctuations was almost 0 rad at ρ = 0.54. On the other hand, the phase shift was not 0 rad at ρ = 0.21, especially in the 100 ∼ 200 kHz region. The high frequency fluctuation at ρ = 0.21 grew on the time scale of 10-5 s, which was obtained from the time dependent signals of the high frequency fluctuation.
Content from these authors
© 2007 by The Japan Society of Plasma Science and Nuclear Fusion Research
Previous article Next article
feedback
Top