2026 Volume 21 Article ID: 1402045
A near-infrared (NIR) spatial heterodyne spectrometer was developed for the hydrogen Paschen-α emission line (Paα, 1,875 nm) to enable temporally and spatially resolved measurements of hydrogen atomic density, temperature, and flow velocity in the edge region of magnetically confined fusion plasmas. To overcome the frame-rate limitations of two-dimensional NIR image sensors, an indium gallium arsenide (InGaAs) linear array was employed, and the interferogram was compressed into one dimension using a custom cylindrical imaging lens system. Spectral measurements of Ne I emission lines in a glow discharge tube confirmed an instrumental wavelength resolution of 125 pm. At zero magnetic field, the measured Paα interferogram in the glow discharge tube exhibited a contrast ratio of approximately 0.58, demonstrating agreement with the numerical model. Furthermore, spectral measurements under magnetic fields up to 3 T demonstrated that spectra influenced by the Zeeman effect were reproducible using fitting functions that incorporate the instrumental function and Doppler broadening. Despite a magnetic field-induced contrast-ratio degradation to approximately 0.4, a signal-to-noise ratio of approximately 20 was achieved at a 1-ms exposure time for a spectral radiance of 1.2 W m−2 sr−1 nm−1, which is comparable to the emission expected in the ITER divertor region.
In fusion-edge plasmas, spatially and temporally resolved measurements of hydrogen atomic density, temperature, and flow velocity are essential for investigating fast phenomena, such as edge-localized modes (ELMs, ≤ 1 ms) [1] and turbulence-driven shear flows (≤ 10 ms) [2], and evaluating their impact on particle and energy transports. For instance, in JT-60U experiments, Type-I ELMs increased the line-integrated edge electron density by approximately 40% via the ionization of recycled atoms, which subsequently recovered to the pre-ELM levels on a millisecond timescale [3]. Furthermore, DIII-D and LHD experiments confirmed the charge-exchange generation of hot atoms in the edge region; these atoms exhibited temperatures closely matching those of the ions, suggesting their relation with transient phenomena, such as ELMs [4–6].
In these previous studies, hydrogen atomic density and temperature were measured via passive spectroscopy of the Balmer-α (Baα) emission line. Although model-based inversions have been applied in some measurements [5, 7], these observations are essentially line-of-sight (LOS)-integrated, limiting the resolution of the local spatial distribution along the LOS. To overcome this limitation, we employ emission-line Zeeman splitting to achieve spatially resolved measurements along the LOS.
A method based on the analysis of Zeeman splitting has been proposed to localize the emission region along a single LOS; this approach has been applied to JET [8], Alcator C-Mod [9], and other devices [10]. To apply this method with further improved spatial resolution, we measure the near-infrared (NIR) Paschen-α emission line (Paα, 1,875 nm) instead of the conventional visible Baα. This choice is based on the fact that Zeeman splitting exhibits a stronger wavelength dependence than Doppler broadening, becoming more pronounced at longer wavelengths [11, 12]. Our previous study demonstrated enhanced spatial resolution using this approach in a divertor-relevant plasma [11].
However, because the Paα emissivity is approximately 20 times lower than that of Baα in an ionizing plasma (assuming an electron temperature of 1 eV and a density of 1021 m−3), it will be challenging to achieve a 1-ms temporal resolution, which is the representative value required for the measurements of fast-edge phenomena, using conventional Czerny–Turner spectrometers (CTSs). Furthermore, Paα measurements necessitate the use of indium gallium arsenide (InGaAs) or mercury cadmium telluride image sensors whose nominal dark noise is typically more than three orders of magnitude higher than that of silicon image sensors used for Baα [13, 14], making it more challenging to acquiring spectra with a sufficiently high signal-to-noise ratio (S/N).
To overcome these limitations, we have developed an NIR spatial heterodyne spectrometer (SHS) [15, 16], a specialized class of Fourier transform spectrometer that operates without requiring mechanical scanning components. Compared with conventional CTSs, SHS provides one to two orders of magnitude higher geometric etendue [17, 18], i.e., enhanced light-collection efficiency, while maintaining a high wavelength resolution on the order of tens to hundreds of picometers. While visible-range SHS systems with temporal resolutions of less than 1 ms have been developed for fusion plasma spectroscopy [17–19], their adaptation to NIR applications remains constrained by the frame-rate limitations of standard two-dimensional image sensors [13, 14]. To address this issue, we adopted an InGaAs linear array detector, which generally enables higher frame-rate than two-dimensional detectors. Previous SHS implementations using linear array detectors relied on digital micromirror device–based scanning system [20, 21], which is incompatible with the high-time-resolution requirements considered here.
In this study, we present the design, numerical modeling, and validation of an NIR SHS optimized for the high-frame-rate measurements of Paα. The remainder of this paper is organized as follows: Section 2 describes the instrument and model, while presenting the performance evaluation. Section 3 describes the feasibility of Zeeman splitting measurements and Doppler broadening analysis in a glow discharge plasma under a fusion-relevant magnetic field.
Figure 1 shows a schematic optical layout of the developed NIR SHS. The emission from the plasma is collected and delivered through an optical fiber (1 mm core diameter, 0.22 NA). The collected light is collimated by a plano-convex lens (25.4 mm diameter, 50 mm focal length), exhibiting a beam diameter of approximately 22 mm and passing through a bandpass filter (1,870 nm central wavelength, 35 nm full width at half maximum (FWHM)). The collimated beam is bifurcated into two beams using a pellicle beamsplitter (45:55, 2 μm thickness). These beams are subsequently diffracted by two reflective gratings (600 grooves mm−1, 28.68° blaze angle) configured at a Littrow angle (θL) of 34.19° for a Littrow wavelength of 1,873.0 nm. The diffracted beams are recombined and demagnified by an imaging lens system to form a wavelength-dependent crossover angle, thereby producing a Fizeau-type interferogram [22], which is detected by an InGaAs linear array (1 × 512 pixels, 25 × 250 μm pixel size, 15 bit, 30 pA dark current, 487 frames s−1). The spectrum is obtained by applying a Fourier transform to the interferogram.

As the detector is a one-dimensional array, the two-dimensional interferogram is compressed along the vertical direction (y-axis in Fig. 1) to ensure that the entire light falls within the effective area of the detector. The imaging lens system comprises five cylindrical lenses whose spacing was optimized to minimize the vertical width and residual aberrations of the compressed interferogram. Lenses L1 (30 × 30 mm, 100 mm focal length) and L2 (30 × 30 mm, 50 mm focal length) are plano-convex cylindrical lenses configured as a telecentric pair to provide a twofold demagnification along the horizontal direction (x-axis in Fig. 1). The subsequent cylindrical lens group (L3) comprises a plano-convex cylindrical lens (25.4 mm diameter, 50 mm focal length), a plano-concave cylindrical lens (15 × 15 mm, 30 mm focal length), and an aspheric-cylindrical lens (12 mm diameter, 10 mm focal length). This combination yields a 175-fold demagnification along the vertical axis, reducing the interferogram height to 125 μm.
The wavelength resolution, as estimated from the FWHM of the instrumental function (described in Sec. 2.3), was 125 pm. The overall transmittance of the spectrometer was approximately 24%; it comprises the transmittances of the major optical components: bandpass filter (80%), pellicle beamsplitter (50%), and imaging lens system (60%). The geometrical etendue (2.8 × 10−8 m2 sr) was obtained by multiplying the fiber etendue (1.2 × 10−7 m2 sr) by the total transmittance.
2.2 Numerical model of the interferogramSince vertical compression modulates the envelope and reduces the contrast ratio of the interferogram, a numerical model of the interferogram was developed to evaluate these effects.
The model was based on physical optics propagation (POP) simulations implemented in ZEMAX OpticStudio [23]. As POP simulations account for diffraction and interference effects associated with finite apertures, wavefront aberrations, and coherent light propagation, it is widely applied to simulate various interferometers (e.g., the Fabry–Pérot and Michelson interferometers) [24]. Unlike geometric ray tracing [23]. POP computes the evolution of the complex wavefront, thereby retaining the phase information. The wavefront is represented on discrete transverse planes, and the corresponding amplitude and phase relationships between these planes are computed using the Fresnel scalar diffraction theory or angular spectrum methods [22]. The detailed calculation procedure is described in Appendix A.
Figure 2 shows the calculated interferograms of the Paα emission lines for H and D atoms, assuming an intensity ratio of

We adjusted the interferogram acquisition conditions according to the measurement objectives. The absolute-intensity and wavelength-calibration data were recorded using an exposure time of 100 ms and averaged over 10 frames. The Paα data were acquired with an exposure time of 1 ms without averaging. The same data-processing procedure was subsequently applied to all interferograms: the DC component (defined in Eq. (A2)) was removed [18], after which the Fourier transform was applied after zero-padding by a factor of 16, where the total data length was 8,192 pixels [25].
Absolute intensity calibration was performed by measuring the spectrum of a home-calibrated stabilized continuum light source (Thorlabs SLS203L/M, 500–9,000 nm). The calibration coefficient for converting the detector count rate to radiance was determined to be approximately 1.6 × 10−3 (W m−2 sr−1 nm−1)/(counts ms−1). The wavelength was calibrated by measuring two Ne I emission lines at 1,859.15 and 1,859.77 nm from a Ne glow discharge tube. Figure 3 shows the measured Ne I spectrum with the model-calculated spectrum. In the calculation, the shapes of the two Ne I emission lines were modeled as delta functions, and their intensities were set to the measured values. The calculated spectrum exhibits a FWHM of approximately 125 pm and reproduces the measured spectrum, with the exception of the side peaks. The larger side peaks observed in the measured spectrum were attributed to the misalignment of the optical components [26]. Consequently, in the subsequent discussion, the measured line shape of the peak at 1,859.77 nm in the wavelength range between the blue dashed vertical lines (0.22 nm width) in Fig. 3 was adopted as the instrumental function. The effect of omitting the side peaks was evaluated subsequently in the fitting analysis by extending the wavelength width to 0.32 and 0.42 nm, which are indicated by the gray dotted vertical lines.

The capability for temporally resolved measurements of the Paα emission line was validated using a deuterium glow discharge tube. Owing to a relatively high neutral pressure (~20 Pa), the radiance of Paα was estimated to be approximately 1.2 W m−2 sr−1 nm−1, which is comparable to that expected during observation of the ITER-divertor plasma, assuming an integration length of 5 cm [27]. The measured and modeled interferograms are shown in Fig. 4(a). The modeled interferogram corresponds to that shown in Fig. 2(a). The contrast ratio

Figure 4(b) shows the measured Paα emission lines of the H and D atoms. The experimental spectrum was fitted using two Gaussian functions corresponding to the Doppler broadening of the H and D atoms, convolved with the instrumental function. The fitting parameters included the peak-intensity ratio,
As interferogram compression reduces

To describe the dependence of the measured S/N on the contrast ratio
| (1) |
where
To assess the extent of S/N degradation caused by aberrations from interferogram compression, a reference case was calculated. The reference assumes an aberration-free imaging lens system corresponding to the pixel-binned interferogram in Fig. 2(a) (
Under an external magnetic field
Figure 6 shows the experimental setup. A custom-fabricated hydrogen glow discharge tube (3 mm inner diameter, 260 mm length) was mounted inside a superconducting magnet (Cryogenic 1721; 7 T maximum field strength). The generated magnetic field was oriented parallel to the discharge-tube axis. The magnetic field inhomogeneity was less than 0.25% over a 10 mm-diameter sphere, including the observation volume; the field was consequently treated as uniform. The DC hydrogen glow discharge was operated at a voltage of 1.4 kV, a current of 12 mA, and a neutral pressure of 20 Pa. Under these conditions, pressure broadening was ignored because it was negligible compared with the instrumental width (125 pm) [28]. Emission was directly collected in the radial direction by the optical fiber that was positioned approximately 2 mm from the discharge-tube outer surface. The viewing direction was oriented approximately perpendicular to the magnetic field. At the plasma center, the cross-sectional diameter of the viewing cone was sufficiently smaller than the plasma-column diameter.

The magnetic field strength was set to
The experimental spectra are shown in Fig. 7. Based on five independent measurements recorded under each magnetic field condition, the measured

The experimental spectra were fitted using a sum of Gaussian functions representing the Doppler broadening of all π and σ components, convolved with the instrumental function. The wavelengths of these components were obtained by calculating the energy levels of the hydrogen atom using first-order perturbation theory [31]. The relative intensities of these components were obtained by calculating their spontaneous emission coefficients and assuming the statistical weights of the upper-state population densities. We also considered the effect of integrating the angular distribution of the emissivity over the fiber acceptance cone [8]. The obtained relative π-to-σ intensity ratio was 0.49/0.51. The Doppler shift was neglected, and
We developed an NIR SHS for the temporally resolved measurements of the Zeeman effect on the hydrogen Paα emission lines. Employing an InGaAs linear array detector and a custom cylindrical imaging lens system, the two-dimensional interferogram was compressed to ensure that the entire light falls within the effective area of the detector while maintaining a high wavelength resolution.
A numerical model incorporating the SHS theory and POP simulation was constructed to quantitatively evaluate the compression impact on the wavelength resolution, contrast ratio
Temporally resolved measurement of Paα emission line spectra under external magnetic fields up to 3 T demonstrated that spectra affected by Zeeman splitting can be reproduced using fitting functions that incorporate the instrumental function and Doppler broadening. Owing to
To elucidate the calculation steps of the numerical model, we first briefly introduce the SHS theory for calculating the interferogram. We define the xyz-coordinate system, as illustrated in Fig. 1. Employing the plane-wave approximation, as well as assuming monochromatic light incidence, the diffracted wavefront,
| (A1) |
where
By neglecting the aberrations introduced by the optical components, the interferogram formed by all rays before the vertical compression by L3 is expressed as follows [17]:
| (A2) |
where the term before the plus sign represents the DC component, while sinc() is a normalized sinc function.
Regarding the numerical modeling procedure, since the phase modulation of a diffraction grating is not incorporated by the POP simulation, we separately applied the SHS theory to calculate
The specific computational steps are as follows:
(1) Calculate
(2) As illustrated in Fig. A1, a sequence of imaging lens surfaces and the sensor plane was modeled in ZEMAX’s sequence mode (Ansys Zemax OpticStudio 2025, student version).

(3) Set a monochromatic plane wave with unit intensity and zero phase at the grating position, denoted as
(4) Propagate
(5) Calculate the transfer function
| (A3) |
where
(6) Calculate the wavefront
As illustrated in Fig. B1, we employed the measured interferogram (dotted curve) in Fig. 4(a) to elucidate the calculation of the contrast ratio,

| (B1) |
where

This work was supported in part by JSPS KAKENHI (Grant No. 24K00604) and the NIFS Collaborative Research Program (Grant No. NIFS25KSPM001). The authors thank all co-workers in the research group for their assistance.