Plasma and Fusion Research
Online ISSN : 1880-6821
ISSN-L : 1880-6821
Rapid Communications
Coincident Measurement of a Weakly Backscattered X-ray with a CPA Laser-Produced X-ray Pulse
Hajime KUWABARAYoshitaka MORIYoneyoshi KITAGAWA
Author information
JOURNAL FREE ACCESS

2008 Volume 3 Pages 003

Details
Abstract
Backscattered X-ray intensity was measured coincidently with a CPA laser-produced X-ray pulse. Results show that the coincident measurement is useful in reducing the effect of natural radiation. Even for signals at the photon counting level, we can distinguish the scattering materials and their thickness from the difference in backscattered X-ray counts. These results suggest that the backscattered X-ray can be used for imaging any distant object.
Content from these authors
© 2008 by The Japan Society of Plasma Science and Nuclear Fusion Research
Previous article Next article
feedback