Plasma and Fusion Research
Online ISSN : 1880-6821
ISSN-L : 1880-6821
Regular Articles
Microwave Imaging Reflectometry Experiment in TPE-RX
Yoshio NAGAYAMASoichiro YAMAGUCHIZhongbing SHIYuichiro KOGIAtsushi MASEShoji SUGITOYoichi HIRANOSatoru KIYAMAHaruhisa KOGUCHIHajime SAKAKITAKiyoyuki YAMBENobuyoshi OHYABU
著者情報
ジャーナル フリー

2008 年 3 巻 p. 053

詳細
抄録
Microwave imaging reflectometry (MIR) was developed in TPE-RX, one of the world's largest reversed field pinch (RFP) devices. The system optics are made of aluminum mirrors, Teflon lenses, and Plexiglas plates in order to reduce size. In this system, frequencies are stabilized so that noise can be reduced using narrow bandpass filters. A 4×4 2-D mixer array and phase detection system have also been developed. With this system, density fluctuations in the high-Θ RFP plasma, pulsed poloidal current drive (PPCD) plasma, and quasi-single helicity (QSH) plasma are observed in TPE-RX. This is the first MIR experiment in an RFP device.
著者関連情報
© 2008 by The Japan Society of Plasma Science and Nuclear Fusion Research