Plasma and Fusion Research
Online ISSN : 1880-6821
ISSN-L : 1880-6821
Regular Articles
High-Density, Low Temperature Ignited Operations in FFHR
Osamu MITARAIAkio SAGARARyuichi SAKAMOTONobuyoshi OHYABUAkio KOMORIOsamu MOTOJIMA
著者情報
ジャーナル フリー

2010 年 5 巻 p. S1001

詳細
抄録
New control method of the unstable operating point in the helical reactor FFHR makes the ignition study on the high density and low temperature operation possible. Proportional-integral-derivative (PID) control of the fueling with the error of the fusion power of e'DT(Pf) = −(Pfo − Pf) can stabilize the unstable operating point. Here Pfo(t) is the fusion power preset value and Pf(t) is the measured fusion power. Although the large parameter variation would lose its control due to the inherently unstable nature, it is possible to control the ignited operation by pellet injection with the pellet size between 12 mm and 16 mm. Unstable ignited operation is robust against disturbances such as impurity increments by fueling feedback alone. However, if the heating power feedback control is added, robustness to the disturbances is improved, and an operational regime with respect to the integration time and derivative time is expanded.
著者関連情報
© 2010 by The Japan Society of Plasma Science and Nuclear Fusion Research
前の記事 次の記事
feedback
Top