Plasma and Fusion Research
Online ISSN : 1880-6821
ISSN-L : 1880-6821
Regular Articles
Development of Microwave Imaging Diagnostics on the HL-2A Tokamak
Zhongbing SHIMin JIANGShao CHENeville C. LUHMANN, Jr.Calvin DOMIERBin WANGYong YINHongjuan SUNZhetian LIUXing HUAlex SPEARJin LIWulu ZHONGWei CHENYoulong CHEBingzhong FUZhengying CUIPing SUNYi LIUXuantong DINGQingwei YANGXuru DUAN
Author information
Keywords: microwave imaging, MIR, ECEI
JOURNAL FREE ACCESS

2014 Volume 9 Pages 3402123

Details
Abstract

Microwave imaging reflectometry (MIR) and electron cyclotron emission imaging (ECEI) systems have been developed on the HL-2A tokamak to visualize the density and temperature fluctuations. The MIR system is comprised of a quasi-optical system, a four frequency microwave source and receiver system that generate 8(poloidal) × 4(radial) × 2(toroidal) = 64 channel images of density fluctuations. The ECEI system is comprised of a quasi-optical system, a front-end 24 channel heterodyne imaging array with a tunable RF from 75 to 110 GHz,and a set of back-end ECEI electronics that together generate 24(poloidal) × 8(radial) = 192 channel images of the 2D temperature fluctuations. Characteristics of both systems are presented. Simulations and laboratory tests of both optical systems have been conducted. The test results are in good agreement with simulations.

Content from these authors
© 2014 by The Japan Society of Plasma Science and Nuclear Fusion Research
Previous article Next article
feedback
Top